Car parking norms in Gurugram
Planning stack, puzzle or tower parking here? See mechanical car parking systems in Gurugram, with prices per bay.
Governing regulation
The Haryana Building Code 2017
Sanctioning authority
DTCP Haryana / HSVP / Municipal Corporation of Gurugram
Verification
07 Oct 2026
13 rows verified
Requirement
How much parking is required
| Applies to | Requirement | Two-wheelers | Visitor | Mechanical | Clause · verified |
|---|---|---|---|---|---|
| Residential | |||||
|
Group housing
At least 5% of the total car parking area to be made available to EWS flats. |
1.5 bays 1.5 ECS per dwelling unit | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(2)
✓ Nov 2026 |
| Plotted colony | 1.5 bays 1.5 ECS per dwelling unit | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(1)
✓ Nov 2026 |
| Commercial | |||||
| Integrated / multi-storey commercial, big box retail, shopping mall | 1 bay 1.0 ECS per 50 sqm of covered area | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(3)
✓ Nov 2026 |
| Shopping areas / designated markets developed by the competent authority | 65% of total site area to be kept for parking | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(5)
✓ Nov 2026 |
| Office / IT | |||||
| Offices, Cyber Park, IT Park, Cyber City | 1 bay 1.0 ECS per 40 sqm of covered area | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(4)
✓ Nov 2026 |
| Hospital | |||||
|
All
Visitor parking 1 ECS per 4 beds (entered as 50% of the 1-per-2-beds requirement). |
1 bay 1.0 ECS per 2 beds, plus 1 ECS per 4 beds for visitors | , | 50% | Permitted |
Haryana Building Code 2017, Code 7.1(6)
✓ Nov 2026 |
| Industrial / Institutional | |||||
|
Industries and institutions
Basis is the permissible FAR of the plot, not the area built. |
1 bay 1.0 ECS per 100 sqm of permissible FAR of plot | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(7)
✓ Nov 2026 |
| Restaurant | |||||
| All | 1 bay 1.0 ECS per 2 seats | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(8)
✓ Nov 2026 |
| Assembly | |||||
| Multiplex / cinema / theatre | 1 bay 1 ECS per 4 seats | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(8)
✓ Nov 2026 |
| Hotel | |||||
|
4 star and above
Employees and visitors: 1 ECS per 3 guest rooms (entered as 33.33%). |
1 bay 1 ECS per guest room, plus 1 ECS per 3 guest rooms for employees and visitors | , | 33.33% | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Nov 2026 |
|
3 star
Employees and visitors: 1 ECS per 4 guest rooms (entered as 37.5% of the guest requirement). |
2 bays 2 ECS per 3 guest rooms, plus 1 ECS per 4 guest rooms for employees and visitors | , | 37.5% | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Nov 2026 |
|
2 star
Employees and visitors: 1 ECS per 5 guest rooms (entered as 50% of the guest requirement). |
2 bays 2 ECS per 5 guest rooms, plus 1 ECS per 5 guest rooms for employees and visitors | , | 50% | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Nov 2026 |
|
Motel
Employees and visitors: 25% of the site area, in addition. |
1 bay 1 ECS per guest room, plus 25% of site area for employees and visitors | , | - | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Nov 2026 |
Calculator
How many bays does your Gurugram project need?
Pick the building type, enter the quantity the rule is based on. Computed from the verified rows above; visitor loading is added and shown separately.
Indicative. The sanctioning authority applies rounding, area-class, TOD and other adjustments a summary cannot capture.
Mechanical parking
Permitted with conditions in Gurugram
What the regulation says
The Haryana Building Code 2017 anticipates mechanical parking in basements and on upper floors and sets a maximum clear height for floors that carry it (Code 7.1(11)). Covered parking in a basement, stilt or multi-level structure is outside FAR (Code 7.1(10)). The code gives no reduced area per ECS for mechanical parking and does not say how a stacked space is counted, so the count is agreed with the sanctioning authority.
Conditions to design around
Dimensions
Bay sizes and geometry
| Bay type | Width | Length | Note |
|---|---|---|---|
| ECS: open | , | , | 23 sqm per ECS (sites other than residential plots) |
| ECS: stilt | , | , | 28 sqm per ECS |
| ECS: basement | , | , | 32 sqm per ECS |
Headroom and structural requirements
Provisions
Loadings, relaxations and clearances
Visitor parking
Relaxations and special cases
Fire clearances
Change log
Amendments since verification
- No amendments recorded since verification.
Record verified 07 Oct 2026 by WAPARKING Team · The Haryana Building Code 2017 , HBC 2017 as hosted by HSVP planning wing (uploaded 31 Aug 2022); Code 7.1 read 07 Oct 2026 . Read the regulation ↗
Can your plot meet this norm?
Send us the plot dimensions and available headroom. We will return a study showing how many bays Gurugram's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.
This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.