Governing regulation

Goa Land Development and Building Construction Regulations, 2010 (GLDBCR)

Sanctioning authority

Town and Country Planning Department, Goa / planning development authorities

Mechanical parking

Permitted with conditions

See conditions ↓

Verification

27 Oct 2026

14 rows verified

Parking in Goa is governed by the Goa Land Development and Building Construction Regulations, 2010 (GLDBCR), administered by the Town and Country Planning Department and the planning development authorities. Regulation 10 and Table IX-A set the minimum off-street parking.

Flats are counted per dwelling unit by floor area, from 1.00 to 2.00 spaces. Most other uses are counted per square metre of floor area; some are stated as a parking area rather than a number of spaces. Each space is at least 12.50 sq m (2.50 m x 5.00 m), excluding circulation.

Requirement

How much parking is required

Applies to Car spaces Two-wheelers Visitor Mechanical Clause · verified
Residential
Flats/apartments: floor area up to 75 sqm

Counted on the floor area of each dwelling unit. More than 10 ECS: at least 20% EV-ready (Reg. 10(g)).

1 bay 1.00 per dwelling unit , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Nov 2026
Flats/apartments: above 75 up to 100 sqm

Counted on the floor area of each dwelling unit. More than 10 ECS: at least 20% EV-ready (Reg. 10(g)).

1.25 bays 1.25 per dwelling unit , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Nov 2026
Flats/apartments: above 100 up to 150 sqm

Counted on the floor area of each dwelling unit. More than 10 ECS: at least 20% EV-ready (Reg. 10(g)).

1.5 bays 1.50 per dwelling unit , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Nov 2026
Flats/apartments: above 150 sqm

Counted on the floor area of each dwelling unit. More than 10 ECS: at least 20% EV-ready (Reg. 10(g)).

2 bays 2.00 per dwelling unit , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Nov 2026
Hotel
Five-star and four-star hotels 1 bay 1 space per 2 rooms , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Other hotels and motels 1 bay 1 space per 4 rooms , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Assembly
Cinemas, theatres, dance halls, public assembly halls 1 bay 1 space per 20 sqm floor area or part , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Stadia

Stated as parking area, not a number of spaces.

Not stated , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Commercial / office
Retail business, restaurants, offices, banks, hospitals, nursing homes 1 bay 1 space per 50 sqm floor area or part , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Commercial
Shopping mall cum multiplex 1 bay 1 ECS per 35 sqm built-up area , - Permitted GLDBCR 2010, Reg. 5A(5)
✓ Oct 2026
Wholesale, warehousing, wholesale markets, market yards

Stated as parking area, not a number of spaces; each space is at least 12.50 sqm excluding circulation (Reg. 10(b)).

Not stated , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Retail markets

Stated as parking area, not a number of spaces.

Not stated , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Educational
Schools and colleges

Stated as parking area, not a number of spaces.

Not stated , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026
Industrial
Industrial premises

Stated as parking area, not a number of spaces.

Not stated , - Permitted GLDBCR 2010, Reg. 10, Table IX-A
✓ Oct 2026

Calculator

How many bays does your Goa project need?

Pick the building type, enter the quantity the rule is based on. Computed from the verified rows above; visitor loading is added and shown separately.

Indicative. The sanctioning authority applies rounding, area-class, TOD and other adjustments a summary cannot capture.

Mechanical parking

Permitted with conditions in Goa

What the regulation says

The regulations refer to mechanical access but have no clause on stack, puzzle or automated parking. Stilted floors at any level should be accessible by “adequate ramps and/or mechanical device” (Reg. 2(126)(a)(ii)). For basements, a car lift may be provided where a ramp is not feasible (Reg. 10(f)).

Conditions to design around

• No rule on how a stacked car counts as an ECS; confirm with TCP or the planning development authority in writing. • Basement parking: at least two ramps, or one ramp at least 5.0 m wide, or a car lift where a ramp is not feasible (Reg. 10(f)). • Stilt floor height capped at 2.85 m (Reg. 2(126)(a)(i)); basement floor height up to 3.50 m (Reg. 2(17)). • More than 10 ECS: at least 20% EV-ready with conduits (Reg. 10(g)).

Dimensions

Bay sizes and geometry

Bay type Width Length Note
Parking space 2.5 m 5.0 m Minimum 12.50 sqm excluding circulation (Reg. 10(b))

Headroom and structural requirements

Basement floor height not more than 3.50 m (Reg. 2(17)). Stilts extending the entire floor: floor height not more than 2.85 m (Reg. 2(126)(a)(i)). Most stack systems need more than 2.85 m, so they usually suit basements or a separate parking structure.

Provisions

Loadings, relaxations and clearances

Visitor parking

Table IX-A has no separate visitor parking figure.

Relaxations and special cases

Parking in excess of the minimum may be considered favourably for relaxation of other requirements, but never FAR, coverage, height or setback (Reg. 10(d)). Ground-floor stilt parking may be exempted if a separate parking structure is built in the same plot; that structure is free of FAR but counts in coverage (Reg. 10(e)).

Fire clearances

Fire and NBC 2016 requirements apply to basement and multi-level parking; they sit outside Regulation 10.

Change log

Amendments since verification

  1. No amendments recorded since verification.

Record verified 27 Oct 2026 by WAPARKING Team · Goa Land Development and Building Construction Regulations, 2010 (GLDBCR) , GLDBCR 2010 compiled to Sept 2024; Reg. 10, Table IX-A (subst. 1 Aug 2011) read 27 Oct 2026 . Read the regulation ↗

Can your plot meet this norm?

Send us the plot dimensions and available headroom. We will return a yield study showing how many bays Goa's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.

Request a free yield audit

This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.