WAParking

Compliance Atlas · Uttar Pradesh

Car parking norms in Greater Noida

Governing regulation

Greater Noida Industrial Development Area Building Regulations, 2010

Sanctioning authority

Greater Noida Industrial Development Authority (GNIDA)

Mechanical parking

Permitted with conditions

See conditions ↓

Verification

07 Nov 2026

8 rows verified

Greater Noida does not follow the UP Model Building Byelaws. Parking is set by Table 5 of the Greater Noida Industrial Development Area Building Regulations, 2010, as substituted in 2013 and amended in 2018. Every figure is counted on permissible FAR area, not on what is built (Table 5, Explanation III).

Requirement

How much parking is required

Applies to Car spaces Two-wheelers Visitor Mechanical Clause · verified
Group housing
All

Counted on permissible FAR area, not built area (Table 5, Explanation III). Visitor parking must be within the plot (Explanation V).

1 bay 1 ECS per 80 sq m of permissible FAR area , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 1(a) (subst. 2013)
✓ Nov 2026
Lodges, guest houses, hotels
All

Visitor parking must be provided within the plot (Table 5, Explanation V).

1 bay 1 space per 2 guest rooms , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 1(b) (subst. 2013)
✓ Nov 2026
IT/ITES, offices, institutions
All

Visitor parking must be provided within the plot (Table 5, Explanation V).

1 bay 1 space per 50 sq m (administrative office) , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 2(a), as revised 2018
✓ Nov 2026
Medical
All

Counted on permissible FAR area, not built area (Table 5, Explanation III). Visitor parking must be within the plot (Explanation V).

1 bay 1 space per 65 sq m of permissible FAR area , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 3 (subst. 2013)
✓ Nov 2026
Commercial
All

Counted on permissible FAR area, not built area (Table 5, Explanation III). Visitor parking must be within the plot (Explanation V).

1 bay 1 space per 50 sq m of permissible FAR area , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 4 (subst. 2013)
✓ Nov 2026
Industrial and storage
All

Counted on permissible FAR area, not built area (Table 5, Explanation III). Visitor parking must be within the plot (Explanation V).

1 bay 1 space per 100 sq m of permissible FAR area , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 5 and 6 (subst. 2013)
✓ Nov 2026
Multiplex / cinema
All

Visitor parking must be provided within the plot (Table 5, Explanation V).

1 bay 1 space per 15 seats , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 8 (subst. 2013)
✓ Nov 2026
Recreational
All

Counted on permissible FAR area, not built area (Table 5, Explanation III). Visitor parking must be within the plot (Explanation V).

1 bay 1 space per 50 sq m of permissible FAR area , - Not permitted GNIDA Building Regulations 2010, Table 5 Sl. 11 (subst. 2013)
✓ Nov 2026

Calculator

How many bays does your Greater Noida project need?

Pick the building type, enter the quantity the rule is based on. Computed from the verified rows above; visitor loading is added and shown separately.

Indicative. The sanctioning authority applies rounding, area-class, TOD and other adjustments a summary cannot capture.

Mechanical parking

Permitted with conditions in Greater Noida

What the regulation says

Mechanical parking is named but not given its own ECS figure. A podium may be served by a ramp "or alternatively mechanized parking as per standard plan" approved by the Authority (Cl. 2.51). Multi-level parking may be mechanized or conventional (Cl. 2.38), with an extra 5% ground coverage on plots over 10,000 sq m (Cl. 24.2.1(3)(xi)).

Conditions to design around

Authority approval of the standard plan for podium mechanisation; CEO approval for basement height above 4.5 m; no rule for counting a pallet as an ECS, so agree pallet counting with the Authority early. Fire NOC applies separately.

Dimensions

Bay sizes and geometry

Bay type Width Length Note
Bay sizes in verification.

Driveways, ramps and headroom

Table 5 Sl. 13 sets area, not bay dimensions: 30 sq m gross per ECS in basement, stilt, podium or covered parking, and 20 sq m for surface parking, each including its share of driveways and ramps. Basement or podium parking area is permitted up to the area equivalent to the parking requirement (Cl. 24.2.1(3)(ii)(b)).

Headroom and structural requirements

Basement height runs from 2.4 m (bottom of beam) to 4.5 m. For an automatic, semi-automatic or mechanised parking facility, more than 4.5 m may be allowed by the CEO depending on the technology (Cl. 24.2.1(11)). Stilts of 2.4 m used for parking are excluded from FAR (Cl. 24.2.1(3)(iv)).

Change log

Amendments since verification

  1. No amendments recorded since verification.

Record verified 07 Nov 2026 by MW (Claude-checked, LegitQuest text) · Greater Noida Industrial Development Area Building Regulations, 2010 , Table 5 subst. 2013 (Reg. 14), Sl. 2 rev. 2018 (Reg. 5); read 07 Nov 2026 . Read the regulation ↗

Can your plot meet this norm?

Send us the plot dimensions and available headroom. We will return a yield study showing how many bays Greater Noida's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.

Request a free yield audit

This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.

Chat with us