WAParking

Compliance Atlas · East Asia · Hong Kong SAR, China

Car parking norms in Hong Kong

Governing regulation

Hong Kong Planning Standards and Guidelines, Chapter 8 (Internal Transport Facilities)

Section 5 Parking Standards; Table 1 (housing), Tables 4 to 6 (commercial)

Sanctioning authority

Planning Department and Transport Department, Hong Kong SAR Government

Mechanical parking

Position not yet verified

See conditions ↓

Verification

18 Nov 2026

4 rows verified

Hong Kong calculates housing parking with a formula, not a fixed number: a base of one space per four to seven flats, scaled up for larger flats and down near rail stations and at high densities. Offices need one space per 150 to 200 sqm for the first 15,000 sqm.

Requirement

How much parking is required

Section 5 Parking Standards; Table 1 (housing), Tables 4 to 6 (commercial)

Applies to Requirement Visitor Mechanical Clause · verified
Residential
Private housing (formula) 1 space per 4 to 7 flats × R1 × R2 × R3 - Permitted Section 5 Parking Standards; Table 1 (housing), Tables 4 to 6 (commercial)
✓ Nov 2026
Office
All 1 space per 150 to 200 sqm GFA (first 15,000 sqm), then 1 per 200 to 300 sqm - Permitted Section 5 Parking Standards; Table 1 (housing), Tables 4 to 6 (commercial)
✓ Nov 2026
Retail
All 1 space per 150 to 300 sqm GFA - Permitted Section 5 Parking Standards; Table 1 (housing), Tables 4 to 6 (commercial)
✓ Nov 2026
Business buildings
All 1 space per 200 to 300 sqm GFA - Permitted Section 5 Parking Standards; Table 1 (housing), Tables 4 to 6 (commercial)
✓ Nov 2026

Mechanical parking

Position not yet verified in Hong Kong

What the regulation says

The HKPSG sets the number of spaces; automated and mechanical car parks are allowed in Hong Kong and the government has piloted automated public car parks, but the standards themselves do not set conditions for them.

Conditions to design around

Dimensions

Bay sizes and geometry

Bay type Width Length Note
Bay sizes in verification.

Provisions

Loadings, relaxations and clearances

Relaxations and special cases

Private housing parking is a formula: Global Parking Standard (1 space per 4 to 7 flats) × R1 (flat size, 0.5 for flats up to 40 sqm rising to 7.0 above 160 sqm) × R2 (0.75 within 500 m of a rail station) × R3 (development intensity, 1.30 at plot ratio up to 1 down to 0.75 above 8). The standards are guidelines; the Authority decides the final provision.

Change log

Amendments since verification

  1. No amendments recorded since verification.

Record verified 18 Nov 2026 by WAP-AE desk verification 19-Nov-2026 · Hong Kong Planning Standards and Guidelines, Chapter 8 (Internal Transport Facilities) , HKPSG Chapter 8 as amended (2023 to 2024 updates to parking standards) . Read the regulation ↗

Can your plot meet this norm?

Send us the plot dimensions and available headroom. We will return a study showing how many bays Hong Kong's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.

Check how many cars fit, free

This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.

Chat with us