UDCPR 2020 — Unified Development Control and Promotion Regulations for Maharashtra

UDCPR 2020, Chapter 8 (Reg. 8.1–8.4; Tables 8-A, 8-B, 8-C)

Sanctioning authority

Pune Municipal Corporation

Authority factor 1

Mechanical parking

Permitted with conditions

See conditions ↓

Verification

07 Oct 2026

37 rows verified

Parking provision in Pune is governed by the Unified Development Control and Promotion Regulations for Maharashtra State, 2020, applied by the Pune Municipal Corporation.

The figures below are a working summary. Requirements are applied with local discretion and are read alongside the Model Building Bye-Laws issued by the Ministry of Housing and Urban Affairs, which recommend two equivalent car spaces for every 100 square metres of built-up area, and the National Building Code, which sets a minimum of 13.75 square metres for a four-wheeler bay.

Requirement

How much parking is required

UDCPR 2020, Chapter 8 (Reg. 8.1–8.4; Tables 8-A, 8-B, 8-C)

Applies to Car spaces Two-wheelers Visitor Mechanical Clause · verified
Residential
Carpet area 150 sqm and above Congested area

Plus 5% visitor parking.

2 bays per tenement 1 per tenement 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area 80 to below 150 sqm Congested area

Plus 5% visitor parking.

1 bay per tenement 1 per tenement 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area 40 to below 80 sqm (per two tenements) Congested area

Plus 5% visitor parking.

1 bay per two tenements 2 per two tenements 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area 150 sqm and above Non-congested area

Plus 5% visitor parking.

2 bays per tenement 1 per tenement 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area 80 to below 150 sqm Non-congested area

Plus 5% visitor parking.

1 bay per tenement 1 per tenement 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area 40 to below 80 sqm (per two tenements) Non-congested area

Plus 5% visitor parking.

1 bay per two tenements 2 per two tenements 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area above 30 to below 40 sqm (per two tenements) Non-congested area

Plus 5% visitor parking.

1 bay per two tenements 2 per two tenements 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area above 30 to below 40 sqm (per two tenements) Congested area

Plus 5% visitor parking.

1 bay per two tenements 1 per two tenements 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Carpet area below 30 sqm (per two tenements)

No car space; two scooter spaces per two tenements. Plus 5% visitor parking.

No car parking required 2 per two tenements 5% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Business / offices
All Non-congested area

Plus 20% visitor parking.

2 bays per 100 sqm carpet area or part 12 per 100 sqm carpet area or part 20% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
All Congested area 1 bay per 100 sqm carpet area or part 12 per 100 sqm carpet area or part 20% Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Mercantile / shops
Shops, showrooms, malls Non-congested area 2 bays per 100 sqm carpet area or part 6 per 100 sqm carpet area or part — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Shops, showrooms, malls Congested area 1 bay per 100 sqm carpet area or part 6 per 100 sqm carpet area or part — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Wholesale
All Non-congested area 1 bay per 100 sqm carpet area or part 5 per 100 sqm carpet area or part — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
All Congested area 1 bay per 100 sqm carpet area or part 4 per 100 sqm carpet area or part — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Office / IT-ITES
All 3 bays per 200 sqm carpet area or part 11 per 200 sqm carpet area or part — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Industrial
All Non-congested area 3 bays per 300 sqm carpet area or part 9 per 300 sqm carpet area or part — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
All Congested area 2 bays per 300 sqm carpet area or part 9 per 300 sqm carpet area or part — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Hospital
Hospitals, medical institutions Non-congested area

Hospitals that are special buildings: space for one ambulance.

3 bays per 10 beds 10 per 10 beds — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Hospitals, medical institutions Congested area

Hospitals that are special buildings: space for one ambulance.

2 bays per 10 beds 12 per 10 beds — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Hotel / lodging
Lodging, tourist homes, hotels incl. star category Non-congested area 1 bay per 5 guest rooms 6 per 5 guest rooms — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Lodging, tourist homes, hotels incl. star category Congested area 1 bay per 5 guest rooms 4 per 5 guest rooms — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Educational
Schools — administrative and public service area Non-congested area

For every 3 classrooms: 5 two-wheelers; mini-bus parking at 1 bus per 40 students for 50% of student strength may be provided at the owner's option, and may be on the playground except during school hours (2022 amendment).

2 bays per 100 sqm carpet of admin and public service area 4 per 100 sqm carpet of admin and public service area — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Schools — administrative and public service area Congested area

For every 3 classrooms: 5 two-wheelers; mini-bus parking at 1 bus per 40 students for 50% of student strength may be provided at the owner's option, and may be on the playground except during school hours (2022 amendment).

1 bay per 100 sqm carpet of admin and public service area 4 per 100 sqm carpet of admin and public service area — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Colleges — administrative and public service area Non-congested area

Plus 2 cars and 24 scooters for every 3 classrooms.

2 bays per 100 sqm carpet 17 per 100 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Colleges — administrative and public service area Congested area

Plus 1 car and 24 scooters for every 3 classrooms.

1 bay per 100 sqm carpet 12 per 100 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Coaching, tuition and hobby classes 1 car and 9 scooters for every 20 students 9 per 20 students — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Assembly
Theatres, cinema houses, concert halls, auditoria, assembly halls 4 bays per 40 seats 16 per 40 seats — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Multiplexes 5 bays per 40 seats 14 per 40 seats — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Mangal karyalaya, marriage, cultural and banquet halls 1 bay per 100 sqm carpet or lawn area 5 per 100 sqm carpet or lawn area — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Restaurant
Restaurants (incl. kitchen, pantry, hall, dining) Non-congested area 1 bay per 50 sqm carpet 8 per 50 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Restaurants (incl. kitchen, pantry, hall, dining) Congested area 0 bays per 50 sqm carpet 8 per 50 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Storage
Storage (any type) Non-congested area 1 bay per 300 sqm carpet 3 per 300 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Storage (any type) Congested area 0 bays per 300 sqm carpet 4 per 300 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Hazardous
Hazardous buildings Non-congested area 1 bay per 100 sqm carpet 3 per 100 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Hazardous buildings Congested area 0 bays per 100 sqm carpet 4 per 100 sqm carpet — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B
✓ Oct 2026
Data centre
Data centre 1 bay 1 car per 400 sqm 0 1 car per 400 sqm — Permitted UDCPR 2020, Reg. 8.2.1, Table 8-B (Sr. 9, inserted 2022)
✓ Oct 2026

Calculator

How many bays does your Pune project need?

Pick the building type, enter the quantity the rule is based on. Computed from the verified rows above; visitor loading is added and shown separately.

Indicative. The sanctioning authority applies rounding, area-class, TOD and other adjustments a summary cannot capture.

Mechanical parking

Permitted with conditions in Pune

What the regulation says

UDCPR 2020 permits mechanical, hydraulic, stack and multi-storeyed parking, with or without car lift, to satisfy the parking requirement. Mechanical bays have their own minimum sizes and the system is sanctioned as part of the parking plan.

Conditions to design around

• Parking plan (bays, aisles, manoeuvring) submitted with the building plan; the system is sanctioned with it. • Stilt minimum 2.4 m below beam; stack parking permitted up to 4.5 m. • Mechanical / stack systems and parking towers may stand in side and rear margins at 1.5 m if a 6.0 m fire driveway stays clear (MFS/51/2024/1140, 18 Jul 2024). • Height limits under the same circular: podium 30 m, standalone MLCP 45 m, fully automated tower up to permissible building height and never above 100 m. • No EV charging inside automated towers, puzzle systems or basements; charging in ventilated areas only. • Stacked/automated parking: sprinklers over every vehicle (two heads per car), 1-hour rated decks, non-perforated steel pallets, emergency stops, detection; fully automated systems 2-hour separated from the building. • Whether dependent (stack) bays count in full is decided at scrutiny — ask PMC Building Permission in writing before designing around stack lifts.

Dimensions

Bay sizes and geometry

Bay type Width Length Note
Standard car bay 2.5 m 5 m Clear of columns
Compact car bay 2.3 m 4.5 m Up to 50% of car spaces
Scooter / motorcycle 1 m 2 m
Transport vehicle / bus 3.75 m 7.5 m Also the loading bay size

Driveways, ramps and headroom

Driveway 3.0 m cars, 2.0 m two-wheelers; 6.0 m clear driveway and 9.0 m turning circle where fire-tender access is required. Ramp gradient 1 in 8; a single ramp is acceptable below 1,000 sqm plot. Stilt clear height 2.4 m minimum; stack parking up to 4.5 m. Composite parking (one car plus two scooters) allowed; six scooter spaces may be converted to one car space. A car space is taken as 12.5 sqm for area purposes.

Headroom and structural requirements

Stilt 2.4 m clear below beam; stack systems up to 4.5 m; two-level puzzle typically 3.6–3.8 m plus ~1.8 m per additional level — confirm against the product before design.

Provisions

Loadings, relaxations and clearances

Visitor parking

Residential: 5% of required car spaces, non-allocatable. Business buildings: 20%. Round up.

Two-wheelers and other vehicles

Scooter spaces run alongside car spaces in Table 8-B. The Table 8-C factor does not apply to two-wheeler parking for multi-family residential (Reg. 8.2.1 note vii).

Relaxations and special cases

Transit Oriented Development: 50% of Table 8-B × 8-C inside a notified TOD zone (Reg. 14.2.1.6) — confirm the notified boundary with PMC. Excess parking above 50% over requirement attracts 10% of ASR land rate on the excess, except hotels, hospitals, educational and public buildings. Additions: requirement reckoned on added area only unless the use changes. Parking is provided for the full permissible potential of the plot even when only part is being built.

Fire clearances

GoM Fire Service circular MFS/51/2024/1140 (18 Jul 2024): podium 30 m, MLCP 45 m, automated tower ≤ permissible height and ≤ 100 m; sprinklers over every stacked vehicle; no EV charging in towers, puzzle systems or basements; 6 m fire driveway retained.

Proof of parking

In April 2025 the Government of Maharashtra circulated a concept note for a state Proof of Parking Policy, and in May 2025 the Transport Minister announced an intention to require evidence of an allotted parking space before a new vehicle may be registered in the Mumbai Metropolitan Region. As at the date of this page the measure is proposed rather than notified. Treat implementation timing as uncertain.

Change log

Amendments since verification

  1. 18 Jul 2024

    Fire safety guidelines for parking structures (MFS/51/2024/1140)

    Directorate of Maharashtra Fire Service circular fixing height limits for parking structures under UDCPR 2020 (podium 30 m, MLCP 45 m, automated tower up to permissible height, max 100 m), sprinkler and pallet requirements for stacked parking, and a bar on EV charging inside automated towers, puzzle systems and basements.

    Source ↗

Record verified 07 Oct 2026 by WAPARKING Team · UDCPR 2020 — Unified Development Control and Promotion Regulations for Maharashtra , UDCPR 2020 consolidated to 30 Jan 2025 (PMRDA copy); Table 8-B/8-C read 07 Oct 2026 . Read the regulation ↗

Can your plot meet this norm?

Send us the plot dimensions and available headroom. We will return a yield study showing how many bays Pune's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.

Request a free yield audit

This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.