WAParking

Compliance Atlas · Delhi

Car parking norms in Delhi

Governing regulation

MPD-2021 as modified by S.O. 3883(E) (2021), read with UBBL 2016

UBBL 2016 (S.O.1191(E), 22 Mar 2016, amended to 2020); MPD 2021 Chapter 12 parking standards

Sanctioning authority

Delhi Development Authority / Municipal Corporation of Delhi (Unified)

Mechanical parking

Permitted

See conditions ↓

Verification

07 Oct 2026

17 rows verified

Requirement

How much parking is required

UBBL 2016 (S.O.1191(E), 22 Mar 2016, amended to 2020); MPD 2021 Chapter 12 parking standards

Applies to Requirement Two-wheelers Visitor Mechanical Clause · verified
Residential
Group housing — dwelling unit 100 to 200 sqm

DU size calculated on FAR area.

2 bays 2.0 ECS per dwelling unit — — Permitted MPD-2021 cl. 4.4.3(B) as modified by S.O. 3883(E), 2021
✓ Oct 2026
Group housing — dwelling unit above 200 sqm

DU size calculated on FAR area.

2.0 ECS per dwelling unit and an additional 1.0 ECS per 100 sqm or part thereof — — Permitted MPD-2021 cl. 4.4.3(B) as modified by S.O. 3883(E), 2021
✓ Oct 2026
EWS / service personnel housing — DU below 40 sqm 0.5 bays 0.5 ECS per dwelling unit — — Permitted MPD-2021 cl. 4.4.3(B) as modified by S.O. 3883(E), 2021
✓ Oct 2026
Group housing — dwelling unit 40 to 100 sqm

DU size calculated on FAR area. Government housing follows GPRA colony norms.

1 bay 1.0 ECS per dwelling unit — — Permitted MPD-2021 cl. 4.4.3(B) as modified by S.O. 3883(E), 2021
✓ Oct 2026
Hostel, guest house, lodging and boarding, dharamshala

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m).

0.5 bays 0.5 ECS per 100 sqm of FAR area — — Permitted MPD-2021 cl. 4.4.3(E) as modified by S.O. 3883(E), 2021
✓ Oct 2026
Plotted housing — plots above 300 sqm

Plots of 250-300 sqm: 2 ECS. If permissible coverage and FAR cannot be achieved, the norm of the preceding category may be used.

1 bay 1 ECS per 100 sqm built-up area — — Permitted MPD-2021 cl. 4.4.3(A)(viii)
✓ Oct 2026
Studio apartments

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m).

1 bay 1.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 cl. 4.4.3(H) as modified by S.O. 3883(E), 2021
✓ Oct 2026
Commercial
Community, district and sub-city centres; Connaught Place

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m) and MLCP deduction (10% if an MLCP is within 1 km).

3 bays 3.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 5.4 as modified by S.O. 3883(E), 2021
✓ Oct 2026
Wholesale / freight complex
Integrated freight complex / wholesale market 3 bays 3.0 ECS per 100 sqm of floor area — — Permitted MPD-2021 Table 6.2 (Wholesale Trade)
✓ Oct 2026
Hotel
All

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m).

2 bays 2.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 5.4 as modified by S.O. 3883(E), 2021
✓ Oct 2026
Service apartments

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m).

2 bays 2.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 5.4 as modified by S.O. 3883(E), 2021
✓ Oct 2026
Hospital / nursing home
Hospital, tertiary health care, nursing home, polyclinic

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m). Government hospitals: 1.0 ECS per 100 sqm FAR area, with Metro and MLCP deductions.

2 bays 2.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 13.2 as modified by S.O. 3883(E), 2021
✓ Oct 2026
Government / institutional offices
Integrated office complex, Government offices

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m) and MLCP deduction (10% if an MLCP is within 1 km). District courts: 2.0 ECS per 100 sqm.

1 bay 1.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 8.2 as modified by S.O. 3883(E), 2021
✓ Oct 2026
Educational
Colleges, universities, vocational and training institutes

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m) and MLCP deduction (10% if an MLCP is within 1 km).

1 bay 1.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 13.6 as modified by S.O. 3883(E), 2021
✓ Oct 2026
Industrial
Industrial plots and flatted group industry

Applies to all industrial plot sizes in Table 7.3.

2 bays 2.0 ECS per 100 sqm of floor area — — Permitted MPD-2021 Table 7.3 (Industrial)
✓ Oct 2026
Assembly
Banquet hall

No Metro or MLCP deduction.

6 bays 6.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 13.17 as modified by S.O. 3883(E), 2021
✓ Oct 2026
Multipurpose community hall, clubs, convention and cultural centres

Less Metro deduction (30% within 500 m of a metro station; 15% at 500-800 m) and MLCP deduction (10% if an MLCP is within 1 km).

2 bays 2.0 ECS per 100 sqm of FAR area — — Permitted MPD-2021 Table 13.17 as modified by S.O. 3883(E), 2021
✓ Oct 2026

Calculator

How many bays does your Delhi project need?

Pick the building type, enter the quantity the rule is based on. Computed from the verified rows above; visitor loading is added and shown separately.

Indicative. The sanctioning authority applies rounding, area-class, TOD and other adjustments a summary cannot capture.

Mechanical parking

Permitted in Delhi

What the regulation says

Delhi measures parking in Equivalent Car Spaces (ECS). Since S.O. 3883(E) of 20 Sep 2021 the norms are per 100 sqm of FAR area, with deductions near metro stations and public multi-level car parks. UBBL 2016 clause 8.3 (high-rise buildings) counts stacked parking and multi-level automated parking at 16 sqm per ECS.

Conditions to design around

• Area per ECS, UBBL 2016 cl. 8.3: open 23 sqm, basement 32 sqm, stilt / podium / roof top 28 sqm, multi-level with ramp 30 sqm, stacked parking 16 sqm, multi-level automated 16 sqm. • Metro deduction: 30% within 500 m of a metro station, 15% at 500–800 m. MLCP deduction: 10% if an MLCP is within 1 km (S.O. 3883(E)). • The revised norms apply to all sites where construction has not begun, even with approved plans; inform the local body in writing. • Fire NOC and NBC 2016 Part 4 apply to parking structures.

Dimensions

Bay sizes and geometry

Bay type Width Length Note
ECS — open — — 23 sqm
ECS — stilt, podium or roof top — — 28 sqm
ECS — basement — — 32 sqm
ECS — multi-level with ramp — — 30 sqm
ECS — stacked or automated — — 16 sqm

Headroom and structural requirements

Stilt 2.4 / 2.7 m; basement per NBC; multi-level per sanctioned plan.

Provisions

Loadings, relaxations and clearances

Visitor parking

S.O. 3883(E) states no separate visitor loading.

Relaxations and special cases

Metro deduction 30% (within 500 m) or 15% (500–800 m); MLCP deduction 10% (within 1 km), where the row says so. Night shelters: no mandatory parking. MPD 2041 not yet notified.

Fire clearances

Delhi Fire Service NOC above 15 m; NBC 2016 Part 4 applies.

Change log

Amendments since verification

  1. No amendments recorded since verification.

Record verified 07 Oct 2026 by WAPARKING Team · MPD-2021 as modified by S.O. 3883(E) (2021), read with UBBL 2016 , S.O. 3883(E), 20 Sep 2021; UBBL 2016 compendium to Aug 2020 (cl. 8.3); read 07 Oct 2026 . Read the regulation ↗

Can your plot meet this norm?

Send us the plot dimensions and available headroom. We will return a yield study showing how many bays Delhi's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.

Request a free yield audit

This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.