Car parking norms in Gurugram
Governing regulation
The Haryana Building Code 2017
Sanctioning authority
DTCP Haryana / HSVP / Municipal Corporation of Gurugram
Verification
07 Oct 2026
13 rows verified
Requirement
How much parking is required
| Applies to | Requirement | Two-wheelers | Visitor | Mechanical | Clause · verified |
|---|---|---|---|---|---|
| Residential | |||||
|
Group housing
At least 5% of the total car parking area to be made available to EWS flats. |
1.5 bays 1.5 ECS per dwelling unit | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(2)
✓ Oct 2026 |
| Plotted colony | 1.5 bays 1.5 ECS per dwelling unit | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(1)
✓ Oct 2026 |
| Commercial | |||||
| Integrated / multi-storey commercial, big box retail, shopping mall | 1 bay 1.0 ECS per 50 sqm of covered area | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(3)
✓ Oct 2026 |
| Shopping areas / designated markets developed by the competent authority | 65% of total site area to be kept for parking | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(5)
✓ Oct 2026 |
| Office / IT | |||||
| Offices, Cyber Park, IT Park, Cyber City | 1 bay 1.0 ECS per 40 sqm of covered area | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(4)
✓ Oct 2026 |
| Hospital | |||||
|
All
Visitor parking 1 ECS per 4 beds (entered as 50% of the 1-per-2-beds requirement). |
1 bay 1.0 ECS per 2 beds, plus 1 ECS per 4 beds for visitors | — | 50% | Permitted |
Haryana Building Code 2017, Code 7.1(6)
✓ Oct 2026 |
| Industrial / Institutional | |||||
|
Industries and institutions
Basis is the permissible FAR of the plot, not the area built. |
1 bay 1.0 ECS per 100 sqm of permissible FAR of plot | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(7)
✓ Oct 2026 |
| Restaurant | |||||
| All | 1 bay 1.0 ECS per 2 seats | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(8)
✓ Oct 2026 |
| Assembly | |||||
| Multiplex / cinema / theatre | 1 bay 1 ECS per 4 seats | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(8)
✓ Oct 2026 |
| Hotel | |||||
|
4 star and above
Employees and visitors: 1 ECS per 3 guest rooms (entered as 33.33%). |
1 bay 1 ECS per guest room, plus 1 ECS per 3 guest rooms for employees and visitors | — | 33.33% | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Oct 2026 |
|
3 star
Employees and visitors: 1 ECS per 4 guest rooms (entered as 37.5% of the guest requirement). |
2 bays 2 ECS per 3 guest rooms, plus 1 ECS per 4 guest rooms for employees and visitors | — | 37.5% | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Oct 2026 |
|
2 star
Employees and visitors: 1 ECS per 5 guest rooms (entered as 50% of the guest requirement). |
2 bays 2 ECS per 5 guest rooms, plus 1 ECS per 5 guest rooms for employees and visitors | — | 50% | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Oct 2026 |
|
Motel
Employees and visitors: 25% of the site area, in addition. |
1 bay 1 ECS per guest room, plus 25% of site area for employees and visitors | — | — | Permitted |
Haryana Building Code 2017, Code 7.1(9), hotel table
✓ Oct 2026 |
Calculator
How many bays does your Gurugram project need?
Pick the building type, enter the quantity the rule is based on. Computed from the verified rows above; visitor loading is added and shown separately.
Indicative. The sanctioning authority applies rounding, area-class, TOD and other adjustments a summary cannot capture.
Mechanical parking
Permitted with conditions in Gurugram
What the regulation says
The Haryana Building Code 2017 anticipates mechanical parking in basements and on upper floors and sets a maximum clear height for floors that carry it (Code 7.1(11)). Covered parking in a basement, stilt or multi-level structure is outside FAR (Code 7.1(10)). The code gives no reduced area per ECS for mechanical parking and does not say how a stacked space is counted, so the count is agreed with the sanctioning authority.
Conditions to design around
Dimensions
Bay sizes and geometry
| Bay type | Width | Length | Note |
|---|---|---|---|
| ECS — open | — | — | 23 sqm per ECS (sites other than residential plots) |
| ECS — stilt | — | — | 28 sqm per ECS |
| ECS — basement | — | — | 32 sqm per ECS |
Headroom and structural requirements
Provisions
Loadings, relaxations and clearances
Visitor parking
Relaxations and special cases
Fire clearances
Change log
Amendments since verification
- No amendments recorded since verification.
Record verified 07 Oct 2026 by WAPARKING Team · The Haryana Building Code 2017 , HBC 2017 as hosted by HSVP planning wing (uploaded 31 Aug 2022); Code 7.1 read 07 Oct 2026 . Read the regulation ↗
Can your plot meet this norm?
Send us the plot dimensions and available headroom. We will return a yield study showing how many bays Gurugram's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.
This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.