Compliance Atlas · Telangana
Car parking norms in Hyderabad
Governing regulation
Telangana Building Rules 2012 (adopted from AP Building Rules 2012, G.O.Ms.No.168)
Rule 12 — Parking requirements (percentage of built-up area), GHMC column
Sanctioning authority
Greater Hyderabad Municipal Corporation (GHMC) / HMDA
Verification
07 Oct 2026
8 rows verified
Requirement
How much parking is required
Rule 12 — Parking requirements (percentage of built-up area), GHMC column
| Applies to | Requirement | Two-wheelers | Visitor | Mechanical | Clause · verified |
|---|---|---|---|---|---|
| Residential | |||||
| Residential apartment complexes | 30% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
| Hospital | |||||
| Hospitals | 30% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
| Institutional / educational | |||||
| Institutional buildings, schools, colleges, other educational buildings | 30% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
| Industrial / godowns | |||||
| Industrial buildings, godowns and others (any use not listed) | 30% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
| Commercial / business | |||||
|
Hotels, restaurants, lodges, cinemas, business and commercial buildings, offices
Same row also covers kalyana mandapams and high-rise buildings of non-residential category. |
40% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
| Shopping malls | |||||
| Shopping malls above 4,000 sqm | 60% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
| IT / ITES complexes | |||||
| IT enabled services complexes | 60% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
| Multiplexes | |||||
| All | 60% of total built-up area as parking | — | — | Permitted |
Building Rules 2012 (G.O.Ms.No.168), Rule 13, Table-V, GHMC column
✓ Oct 2026 |
Mechanical parking
Permitted with conditions in Hyderabad
What the regulation says
Building Rules 2012 express the requirement as a percentage of total built-up area (Rule 13, Table-V). Rule 13(b)(vi): where mechanical systems and car lifts enabling two-tier parking are proposed, the required parking is computed accordingly. Access to parking may be through mechanical lifts instead of ramps (Rule 13(c)).
Conditions to design around
Dimensions
Bay sizes and geometry
| Bay type | Width | Length | Note |
|---|---|---|---|
| Bay sizes in verification. | |||
Driveways, ramps and headroom
Headroom and structural requirements
Provisions
Loadings, relaxations and clearances
Visitor parking
Two-wheelers and other vehicles
Relaxations and special cases
Fire clearances
Change log
Amendments since verification
- No amendments recorded since verification.
Record verified 07 Oct 2026 by WAPARKING Team · Telangana Building Rules 2012 (adopted from AP Building Rules 2012, G.O.Ms.No.168) , G.O.Ms.No.168 MA&UD, 7 Apr 2012; Rule 13 Table-V read 07 Oct 2026 . Read the regulation ↗
Can your plot meet this norm?
Send us the plot dimensions and available headroom. We will return a yield study showing how many bays Hyderabad's requirement needs, how many the site gives conventionally, and how many it gives mechanically. Free, within seventy-two hours.
This page is a reference, not a sanction. Parking requirements change and are applied with local discretion; cite the authority document, not this summary, and confirm the current position with the sanctioning authority before making a submission. WAParking accepts no liability for reliance on this summary.